Automotive Electronics

Automotive Electronics

Comprehensive Testing Solutions

  • Charging Systems

  • Low- and High-Voltage Battery Systems

  • Radiated Immunity Testing
  • Automotive Transient Emissions Test System

    The automotive transient disturbance test system TES-50 is suitable for transient conducted emission tests required by standards ISO 7637-2 and GB/T 21437-2. TES-50-MS is a standard automotive relay designed to measure transient emissions with amplitudes exceeding 500V. TES-50-ES is a semiconductor electronic switch used to measure transient emissions with an amplitude less than 500V.
    According to standards: ISO 7637-2, GB/T 21437-2, etc.

    Automotive Transient Emissions Test System

    Features

    Features
    1. Fully meets ISO 7637-2 emission test standards
    2. The two switch positions of ES and MS can be interchanged at will.
    3. Test voltage can reach 80V DC, continuous current 50A, larger current products can be customized
    1. The 1-inch LCD screen displays the on-off time, with automatic, manual or external trigger switching characteristics.
    2. Built-in RS resistor, automatic switching
    3. Contains temperature overheat alarm function

    Technical Specifications

    Technical specifications
    No.ParameterValue
    1 Power Supply AC110V-240 V,50Hz/60Hz 5A
    2 Monitoring interface N type 1:1 coaxial terminal output
    3 Parallel resistor [Rs]:EXT.,10 Ω,20 Ω,40 Ω,120 Ω
    4 Trigger mode Automatic, single, external trigger
    5 Mode selection Mechanical switch, electronic switch
    6 Instrument ground connection method ≤10 mm Banana Plug Cable
    7 DUT capacity 80 VDC 50A
    8 Size (L*W*H) 330*320*205 (not including socket)
    9 working environment Temperature: 15℃–35℃ Humidity: 45%–75%
    10 Weight about 10kg
    Artificial power network parameters
    1 Frequency 0.1 MHz-100 MHz
    2 capacitor 0.1μF
    3 impedance 5 μH||50 Ω, in accordance with ISO 7637-2 impedance curve
    4 DC resistance <5 mΩ
    Electronic switch parameters TES-50-ES
    1 Turn on and turn off time 0.01~99.99 s+(10%+10 ms)
    2 Voltage Drop <2 V@25 A,typical 2.3 V@50 A
    3 switching time 300nS+20%@load 50uH/0.6 Ω
    4 Transient protection voltage 440 V
    Mechanical switch parameters TES-50-MS
    1 Turn on and turn off time 0.01~99.99 s+(10%+10 ms)
    2 Maximum switching current 50A
    3 contact point High purity silver, no inhibition on contacts
    4 action time Close: 20mS Open: 10mS
    5 Size (L*W*H) 120*215*155 (excluding socket)
    6 Weight Approximately 1.7 kg
    Calibration module ATDTS-CAES (optional)
    1 input voltage 13.5 V
    2 Inductive load 0.6Ω 、50μH
    3 ambient temperature 15℃~35℃
    4 Length×width×height 500 mm×500 mm×600 mm