Comprehensive Testing Solutions

  • Charging Systems

  • Low- and High-Voltage Battery Systems

  • Radiated Immunity Testing
  • Wire Harness Micro-Interruption Simulator

    The wire harness micro-interruption simulator LMI-216 is based on ISO16750-2 (2023), which can meet the E-10 and E-13 provisions of the VW80000 and LV124 standards. The waveform rise and fall time is 200ns, and meets the test requirements of GMW3172 9.2.18 and 9.2.19. Supports Volkswagen and Audi's latest voltage change rate testing requirements. Supports square wave duty cycle test, and the square wave duty cycle can be set arbitrarily. The power cord supports positive and negative interruptions. The signal line supports single-channel and multiple-channel simultaneous testing, with a maximum of 16 channels, and the channels can be switched.
    According to standards: ISO16750-2(2023), VW80000, LV124, GMW3172, etc.

    Wire Harness Micro-Interruption Simulator

    Features

    Features
    1. It has built-in standard libraries and standard waveforms, supports calling edited standard test files, and provides customization of specific standard libraries before leaving the factory.
    2. The maximum power line micro-interruption test current is 50/100/200A and can be customized.
    3. 19-Inch 4U Standalone Chassis, Total Weight ≤10 kg.
    4. Full touch screen, input four-quadrant control, intelligent anti-accidental touch, automatic alarm.
    5. Interrupt switches S+ and S- are built-in.
    1. The interrupt waveform is smooth and burr-free.
    2. Various voltage change rates, low internal resistance, and interrupt parameters are programmable.
    3. The device can be used alone and supports one-click calibration.
    4. Multiple Programmable Interfaces; Supports Remote Control and Mouse/Keyboard Operation.

    Applicable Standards

    Standard
    ISO16750-2(2023) VW80000 GMW3172

    Technical Specifications

    No.ParameterValue
    Power line micro-interruption parameters
    1 S2 bleeder resistor Open Circuit, 0 Ω, 0.1 Ω, 1 Ω, 100 Ω
    2 internal resistance < 50mΩ
    3 Maximum voltage, current 80V, 50/100/150A /200A can be customized
    4 Rise and fall time < 200ns
    5 Waveform distortion rate < 5%
    6 voltage change rate > 100V/µS、 ≥20V/µS
    7 Start/stop time 1 µs~200s
    8 Interrupt time stepping support
    9 Peak current range (50A model) continuous current 100A, maintenance time 200ms, 500A continuous 1ms
    Signal line micro-interruption parameters
    1 internal resistance ≤50mΩ
    2 Maximum voltage, current 40V、3A
    3 Rise and fall time < 200ns
    4 Waveform distortion rate < 5%
    5 Start/stop time 1 µs~200S
    6 Interrupt data programming support
    7 Peak current range Maximum 3A for 200mS
    Common parameters
    1 Calibration accessories The signal line is equipped with 1Ω and 1000Ω as standard, and the power line is equipped with 1Ω and 100Ω as standard.
    2 Interfaces LAN、USB、RS485
    3 Operating Environment Temperature: 10°C–40°C; Humidity: 30%–70%
    4 Power Supply AC:110~250V 50Hz/60Hz
    5 Volume/weight Width 460mm × Height 180mm × Depth 550mm/8kg

    Selection Guide

    ModelTechnical SpecificationsDimensions / Power Supply
    LMI-216 Wire harness micro-interruption simulator,: S2 bleeder resistor, open circuit, 0Ω, 0.1Ω, 1Ω, 100Ω; internal resistance < 50mΩ; maximum voltage, current, 80V, 50A 4U/19" standard chassis 220VAC10A
    LMI-216-100 Wire harness micro-interruption simulator,: S2 bleeder resistor, open circuit, 0Ω, 0.1Ω, 1Ω, 100Ω; internal resistance < 50mΩ; maximum voltage, current, 80V, 100A 4U/19" standard chassis 220VAC10A
    LMI-216-200 Wire harness micro-interruption simulator,: S2 bleeder resistor, open circuit, 0Ω, 0.1Ω, 1Ω, 100Ω; internal resistance < 50mΩ; maximum voltage, current, 80V, 200A 4U/19" standard chassis 220VAC10A
    Other Specifications Can Be Customized upon Request