Military EMC Test Equipment

Military EMC Test Equipment

Comprehensive Coverage of Demanding Military and Aerospace EMC Testing

  • MIL-CS106\MIL-CS114\MIL-CSI15\MIL-CS116S

  • D0160-S19
  • Bulk Cable Injection Conducted Susceptibility Test System

    The cable bundle injection conduction sensitivity test system MIL-CS114 adopts an integrated design with built-in signal synthesizer, three-channel power meter, RF power amplifier dual directional coupler, etc. It can output CW, AM, PM and other modulated or unmodulated RF signals from 4kHz to 400MHz. The wide input range power meter can detect power signals from -85DBm to 20DBm without interruption. Selectable average mode or pulse mode to handle detecting amplitude modulated or pulse modulated signals. Each part can work independently, and an external power amplifier can be used. The truly one-piece design makes calibration faster, and all frequency points can be calibrated in just tens of seconds.
    The cable bundle injection conduction sensitivity test system MIL-CS114 is used to test the injection conduction sensitivity of military cable bundles.
    According to standards: GJB 151A-1997, GJB 152A-1997, GJB 151B-2013, etc. CS114 test requirements.

    Bulk Cable Injection Conducted Susceptibility Test System

    Features

    Features
    1. It has built-in standard libraries and standard waveforms, supports calling edited standard test files, and provides customization of specific standard libraries before leaving the factory.
    2. Supports large current injection (with current injection clamp), optional current monitoring probe, and supports closed-loop testing method.
    3. The power meter supports pulse detection mode to facilitate testing in the military industry.
    4. The signal synthesizer, power meter, and power amplifier can be used separately and support one-click calibration.
    1. Multiple Programmable Interfaces; Supports Remote Control and Mouse/Keyboard Operation.
    2. The entire calibration time is less than 1 minute.
    3. 1-inch capacitive touch screen, input four-quadrant control.
    4. 4U/19-inch standard chassis, total weight ≤20Kg.

    Applicable Standards

    Standard
    GJB 151A-1997 GJB 152A-1997 GJB 151B-2013

    Technical Specifications

    Technical specifications
    No.ParameterValue
    signal generator
    1 Frequency Range 4kHz-400MHz
    2 frequency resolution 1Hz
    3 Frequency temperature stability ±0.5ppm
    4 Harmonics ≤-30dBc
    5 non-harmonic ≤-50dBc
    6 Output power range -100dBm~3dBm
    7 amplitude modulation Modulation frequency: 1Hz~10kHz; Modulation depth: 1%~99%, internal modulation/external modulation
    8 pulse modulation Modulation frequency: 1Hz~10kHz; Duty cycle: 1%~99%
    Power meter x3
    1 Frequency Range 4kHz-400MHz
    2 input range -85dBm-+10dBm
    3 Accuracy ±0.5 dB
    4 Sampling mode average, integral, pulse
    5 Input interface SMA on the front panel, N head on the rear panel
    amplifier
    1 Applicable Standards GJB151B-CS114
    2 Frequency Range 4kHz-400MHz
    3 Output Power 120W 54DB
    4 Output Interface Rear panel N head
    Dual directional coupler
    1 Frequency Range 10kHz-400MHz
    2 Attenuation ratio 50DB
    3 Maximum Input Power 300W
    Common parameters
    1 Interfaces LAN、USB、RS485
    2 Operating Environment Temperature: 10°C–40°C; Humidity: 30%–70%
    3 Power Supply AC:110~250V/10A 50Hz/60Hz
    4 Dimensions and Weight Width 460mm × Height 180mm × Depth 550mm 10kg

    Accessory Specifications

    Accessory Specifications
    No.ParameterValue
    Current Injection Probe BCP-410
    1 Frequency Range 10kHz-400MHz
    2 maximum attenuation 10DB
    3 Inner Diameter × Outer Diameter × Height 40x128x136mm
    4 Maximum Input Power 100W
    Calibration fixture CCF-500
    1 Frequency Range DC-500MHz
    2 voltage standing wave ratio 2:1
    3 Weight 3.5KG
    Current Monitoring Probe BCM-410
    1 Frequency Range 10kHz-400MHz
    2 Maximum through current 100A
    3 Inner Diameter × Outer Diameter × Height 40x80x40mm
    Attenuator RF-6DB10
    1 Frequency Range DC-4GHz
    2 Gain 6DB
    3 Maximum power 100W