Commercial EMC Test Equipment

Commercial EMC Test Equipment

Comprehensive
Coverage
of International Standards

RF Conducted Immunity Test System

The RF conducted immunity test system CSR-608 adopts an integrated design with built-in signal synthesizer, power meter, RF power amplifier dual directional coupler (optional), etc. It can output CW, AM, PM and other modulated or unmodulated RF signals from 100kHz to 300MHz. The wide input range power meter can detect power signals from -85DBm to 10DBm without interruption. Selectable average mode or pulse mode to handle detecting amplitude modulated or pulse modulated signals. Each part can work independently, and an external power amplifier can be used. The truly one-piece design makes calibration faster, and all frequency points can be calibrated in tens of seconds.
The RF conducted immunity test system CSR-608 is used for conducted immunity testing of civilian products.
According to standards: IEC61000-4-6 and GB/T 17626.6, etc.

RF Conducted Immunity Test System

Features

Features
  1. It has built-in standard libraries and standard waveforms, supports calling edited standard test files, and provides customization of specific standard libraries before leaving the factory.
  2. Supports large current injection (with current injection clamp), optional current monitoring probe, and supports closed-loop testing method.
  3. The power meter supports pulse detection mode to facilitate testing in the military industry.
  4. The signal synthesizer, power meter, and power amplifier can be used separately and support one-click calibration.
  1. Multiple Programmable Interfaces; Supports Remote Control and Mouse/Keyboard Operation.
  2. The entire calibration time is less than 1 minute.
  3. 1-inch capacitive touch screen, input four-quadrant control.
  4. 4U/19-inch standard chassis, total weight ≤20Kg.

Applicable Standards

Standard
IEC61000-4-6 GB/T 17626.6

Technical Specifications

Technical specifications
No.ParameterValue
signal generator
1 Frequency Range 100kHz-300MHz
2 frequency resolution 1Hz
3 Frequency temperature stability ±0.5ppm
4 Harmonics ≤-30dBc
5 non-harmonic ≤-50dBc
6 Output power range -100dBm~3dBm
7 amplitude modulation Modulation frequency: 1Hz~10kHz; Modulation depth: 1%~99%, internal modulation/external modulation
8 pulse modulation Modulation frequency: 1Hz~10kHz; Duty cycle: 1%~99%
Power meter x3
1 Frequency Range 100kHz-300MHz
2 input range -85dBm-+10dBm
3 Accuracy ±0.5 dB
4 Sampling mode average, integral, pulse
5 Input interface SMA on the front panel, N head on the rear panel
amplifier
1 Applicable Standards IEC61000-4-6
2 Frequency Range 100kHz-300MHz
3 Output Power 80W 50DB gain
4 Output Interface Rear panel N head
Common parameters
1 Interfaces LAN、USB、RS485
2 Operating Environment Temperature: 10°C–40°C; Humidity: 30%–70%
3 Power Supply AC:110~250V/10A 50Hz/60Hz
4 Dimensions and Weight Width 460mm × Height 180mm × Depth 550mm 10kg

Accessory Specifications

Accessory Specifications
No.ParameterValue
Electromagnetic injection forceps EIF-230
1 Frequency Range 100kHz-230MHz
2 maximum attenuation 10DB
3 Maximum wire diameter 20mm
4 Length × Width × Height 640x100x100mm
5 Maximum Input Power 100W
Power cord network M3-16 / M3-32 / M5-32
1 Frequency Range 10kHz-230MHz
2 Maximum operating voltage and current 250VAC,100VDC、16A/32A
3 Coupling Impedance 150Ω
4 coupling network M3: Switchable Between Single-Phase 2-Wire and 3-Wire; M5: Switchable Between Three-Phase 4-Wire and 5-Wire
Coaxial load RL-50
1 Frequency Range DC-3GHz
2 Maximum power 50W
3 impedance 50Ω
4 Output Interface N-Type Coaxial