Power-Frequency Magnetic Field Immunity Simulator

The power frequency magnetic field interference simulator PMF-8xx series is a high-reliability test instrument specially designed for the characteristics and requirements of power frequency magnetic field immunity testing of electrical and electronic products. This instrument can provide an accurate basis for the immunity test of the power frequency magnetic field of the equipment under test. It can simulate the magnetic field environment of residential buildings, commercial areas, industrial and mining enterprises and discharge plants, as well as medium and high substations.
According to standards: IEC 61000-4-8 and GB/T 17626.8, etc.

Power-Frequency Magnetic Field Immunity Simulator

Features

Features
  1. Magnetic field strength range: 1A/m~1000A/m
  2. 1A/m~100A/m no time limit, 100A/m~1000A/m supports up to 5S
  3. Magnetic field distortion rate <3%
  4. 1-inch capacitive touch display, all operations can be completed on the screen
  5. Built-in standard library supports customization of specific standard libraries before leaving the factory.
  1. Meets proximity and intrusion test
  2. The output current is displayed in real time.
  3. Multiple Programmable Interfaces; Supports Remote Control and Mouse/Keyboard Operation.
  4. 4U/19-inch standard chassis, total weight ≤20Kg.

Applicable Standards

Standard
IEC 61000-4-8 GB/T 17626.8

Technical Specifications

Technical specifications
No.ParameterValue
1 Magnetic field output strength 1~1000A/m Resolution: 1A/m
2 Output current distortion rate <3%
3 Output frequency 50Hz/60Hz
4 Waveform interval time 1~99999S
5 Test duration No time limit below 100A/m, 1~5S above 100A/m
6 Secondary development Support external trigger and remote control
7 Languages Switchable Between Chinese and English
8 Operating Environment Temperature: 10°C–40°C; Humidity: 30%–70%
9 Input Power AC:100~250V@50Hz/60Hz
10 Overall dimensions 4U/19" standard chassis
11 Weight 25kg
Single turn magnetic field antenna
1 size 1m×1m rectangle
2 Magnetic field strength No time limit below 400A/m, 1~5S above 400A/m
3 angle Can be tested at 360° without dead angle, meeting proximity method and intrusion method
4 Dimensions (length, width and height) 1.2m×0.5m×1.5m
5 Weight 17kg