Automotive Electronics

Automotive Electronics

Comprehensive Testing Solutions

  • Charging Systems

  • Low- and High-Voltage Battery Systems

  • Radiated Immunity Testing
  • Bulk Current Injection Test System

    The large current injection test system BCI-1204 adopts an integrated design with built-in signal synthesizer, three-channel power meter, RF power amplifier, dual directional coupler, etc. It can output CW, AM, PM and other modulated or unmodulated RF signals from 9kHz to 400MHz. The wide input range power meter can detect power signals from -85DBm to 10DBm without interruption. Selectable average mode or pulse mode to handle detecting amplitude modulated or pulse modulated signals. Each part can work independently, and an external power amplifier can be used. The truly one-piece design makes calibration faster, and all frequency points can be calibrated in just tens of seconds.
    According to standards: ISO11452-4, GB/T33014.4, GB/T17619, SAE J1113-4, etc.

    Bulk Current Injection Test System

    Features

    Features
    1. It has built-in standard libraries and standard waveforms, supports calling edited standard test files, and provides customization of specific standard libraries before leaving the factory.
    2. Supports large current injection (with current injection clamp), optional current monitoring probe, and supports closed-loop testing method.
    3. The power meter supports pulse detection mode to facilitate testing in the military industry.
    4. The signal synthesizer, power meter, and power amplifier can be used separately and support one-click calibration.
    1. Multiple Programmable Interfaces; Supports Remote Control and Mouse/Keyboard Operation.
    2. The entire calibration time is less than 1 minute.
    3. 1-inch capacitive touch screen, input four-quadrant control.
    4. 4U/19-inch standard chassis, total weight ≤20Kg.

    Applicable Standards

    Standard
    ISO11452-4 GB/T33014.4 GB/T17619 SAE J1113-4

    System technical parameters

    Technical specifications
    No.ParameterValue
    signal generator
    1 Frequency Range 9kHz-400MHz
    2 frequency resolution 1Hz
    3 Frequency temperature stability ±0.5ppm
    4 Harmonics ≤-30dBc
    5 non-harmonic ≤-50dBc
    6 Output power range -100dBm~3dBm
    7 amplitude modulation Modulation frequency: 1Hz~10kHz; Modulation depth: 1%~99%, internal modulation/external modulation
    8 pulse modulation Modulation frequency: 1Hz~10kHz; Duty cycle: 1%~99%
    Power meter x3
    1 Frequency Range 9kHz-400MHz
    2 input range -85dBm-+10dBm
    3 Accuracy ±0.5 dB
    4 Sampling mode average, integral, pulse
    5 Input interface SMA on the front panel, N head on the rear panel
    amplifier
    1 gain range 50~54DB
    2 Frequency Range 100kHz-400MHz
    3 Output Power 120W 51DBm / 200W 53DBm
    4 Output Interface Rear panel N head
    Dual directional coupler
    1 Frequency Range 100kHz-400MHz
    2 Attenuation ratio 50DB
    3 Maximum Input Power 300W
    Common parameters
    1 Interfaces LAN、USB、RS485
    2 Operating Environment Temperature: 10°C–40°C; Humidity: 30%–70%
    3 Power Supply AC:110~250V/10A 50Hz/60Hz
    4 Dimensions and Weight 460mm×180mm×550mm 10kg
    5 other Other power or external amplifiers can be customized

    BCI high current injection test system accessories parameters

    No.ParameterValue
    Current Injection Probe BCP-410
    1 Frequency Range 10kHz-400MHz
    2 maximum attenuation 10DB
    3 Inner Diameter × Outer Diameter × Height 40x128x136mm
    4 Maximum Input Power 100W
    5 Output terminal N-Type Coaxial
    Calibration fixture CCF-500
    1 Frequency Range DC-500MHz
    2 voltage standing wave ratio 2:01
    3 Weight 3.5KG
    4 size 260*170*146mm
    5 Output terminal N-Type Coaxial
    Current Monitoring Probe BCM-410
    1 Frequency Range 10kHz-400MHz
    2 Maximum through current 100A
    3 Inner Diameter × Outer Diameter × Height 40x80x30mm
    Attenuator RF-6DB10
    1 Frequency Range DC-3GHz
    2 Gain 6DB
    3 Maximum power 100W
    4 Interfaces N-Type Coaxial
    Coaxial load RL-50
    1 Frequency Range DC-3GHz
    2 Maximum power 50W
    3 impedance 50Ω
    4 Output Interface N-Type Coaxial
    Artificial power network LISN-50
    1 Frequency Range 10kHz-108MHz
    2 Maximum working voltage 250VAC,100VDC
    3 Maximum working current 50A
    4 equivalent circuit (5µH+1Ω)//50Ω
    5 Output Interface 6 mm Banana Jack

    Selection Guide

    Selection Guide
    ModelTechnical SpecificationsDimensions / Power Supply
    BCI-1204 BCI high current injection test system, built-in signal synthesizer, three-channel power meter, RF power amplifier dual directional coupler, frequency range: 100kHz-400MHz; output power, 120W 50DB 4U/19" standard chassis 220VAC10A
    BCI-2004 BCI high current injection test system, built-in signal synthesizer, three-channel power meter, RF power amplifier dual directional coupler, frequency range: 100kHz-400MHz; output power, 200W 50DB 4U/19" standard chassis 220VAC10A
    Other Specifications Can Be Customized upon Request