Electrostatic Discharge Simulator

Static electricity between the human body and an object or between two objects can sometimes produce a voltage of tens of thousands of volts, which may cause circuit malfunction or even damage to electrical and electronic equipment.
The electrostatic discharge simulator ESD-20A is an advanced intelligent electrostatic discharge generator with a maximum output voltage of 20kV. It is also an independently developed and produced electrostatic discharge simulator that integrates discharge gun head and touch screen control. The LCD touch screen is simple and easy to operate, and the RC module is replaceable, ensuring reliability in various testing situations.
According to standards: ISO 10605, GB/T 19951, GB/T17626.2, IEC61000-4-2, etc.

Electrostatic Discharge Simulator

Features

Features
  1. The maximum output voltage can reach 20kV
  2. Contact discharge and air discharge modes can be replaced
  3. Standard 150 pF and 330 Ω Discharge Modules; Replaceable
  4. Adopting dual high-voltage power supplies, greatly extending the service life
  5. Automatic switching of positive and negative poles
  1. 7-inch color LCD display, easy to operate
  2. Air discharge voltage holding time>5s
  3. Accurate voltage output
  4. Multiple test methods, supporting single, multiple, and 20pps scanning modes
  5. 1,000 groups of test memories are saved, supporting naming for easy recall of tests.

Applicable Standards

Standard
ISO 10605 GB/T 19951 GB/T17626.2 IEC61000-4-2

Technical Specifications

Technical specifications
No.ParameterValue
1 Output Voltage 0.2kV-20kV ± 5%
2 Rise Time 0.8ns ±25%
3 discharge interval 0.05-99.99S, (in 20ppS mode, the discharge interval is 0.05S)
4 Number of discharges 1-9999 (0 means infinite)
5 Output polarity Positive, negative, positive first then negative, negative first then positive
6 trigger mode Single, counting, 20ppS
7 discharge mode Contact discharge or air discharge
8 discharge electrode Pointed Tip (Contact Discharge) / Rounded Tip (Air Discharge)
9 Discharge module 150pF/2000Ω、150pF/330Ω、330pF/330Ω、330pF/2000Ω
10 hold time Air discharge mode is greater than 5S
11 Operating Environment Temperature: 15°C-35°C relative humidity 10%-75%
12 System power AC220±10%, 50/60Hz, about 300W
13 Dimensions and Weight Width 260mm × Height 170mm × Depth 360mm 8kg